Applications of Machine Learning Algorithms in Renewable Energies
Majid Baseer
Abstract
Short-term load forecasting (STLF) studies can report strong accuracy when target construction, data provenance, units, and forecast-time information are not audited. This study presents a methodological audit using 189,888 quarter-hourly records labelled from January 2020 to May 2025. Although complete, ...
Read More
Short-term load forecasting (STLF) studies can report strong accuracy when target construction, data provenance, units, and forecast-time information are not audited. This study presents a methodological audit using 189,888 quarter-hourly records labelled from January 2020 to May 2025. Although complete, the dataset’s provenance cannot be independently verified, and its target follows the near-exact construction: Load = 1500 + 100(Temperature − 28). Load values are therefore reported in source units rather than asserted physical kW.
The diagnostic contribution demonstrates how target reconstruction, chronological splitting, forecast-information checks, interpretable baselines, and explicit claim boundaries alter the interpretation of an apparently high-performing STLF experiment. Ordinary Least Squares is exact because it recovers the construction rule. Random Forest and Gradient Boosting are retained as falsification benchmarks, not evidence of algorithmic competition. Near-zero correlations and feature importance for other variables confirm that the dataset does not represent realistic multivariate or autoregressive demand dynamics.
Because realized temperature appears to be available at prediction time, the nominal metrics represent ex-post conditional fit rather than deployable ex-ante forecasting accuracy. Without fabricating observations, an analytical stress test propagates temperature-forecast error and independent load noise through the recovered equation. Temperature-error standard deviations of 0.5, 1.0, and 2.0 °C imply RMSE values of 50, 100, and 200 source units, respectively, before behavioral noise. The study provides a reproducible audit protocol and negative methodological result: accuracy, uncertainty, renewable-integration relevance, and operational value cannot be inferred from constructed targets without verified measured demand, issue-time weather forecasts, renewable generation, and system constraints.
Photovoltaic Systems
Muhammad Fawad Saleem; Majid Baseer; Ahmad Khan; Sardar Ahmed Imtiaz
Abstract
Net-Zero Energy Buildings (NZEBs) designed for present climatic conditions face a dual mid-century challenge: rising cooling demand increases electricity consumption, while climate-related photovoltaic (PV) losses reduce on-site generation. This study introduces the Net-Zero Divergence Factor (DF), a ...
Read More
Net-Zero Energy Buildings (NZEBs) designed for present climatic conditions face a dual mid-century challenge: rising cooling demand increases electricity consumption, while climate-related photovoltaic (PV) losses reduce on-site generation. This study introduces the Net-Zero Divergence Factor (DF), a normalized, additive metric quantifying the combined erosion of net-zero performance over time. The framework is applied to a 511 m² office building in Karachi, Pakistan, from 2025 to 2050 under the HadCM3 A2 scenario. Climate-adjusted weather files are generated using CCWorldWeatherGen, building loads simulated in EnergyPlus v25.2, and PV generation modelled in PVSyst v7.4.7. Mid-century climate drift erodes 5.13% ± 1.50% of baseline annual load, comprising a 10.02% increase in cooling electricity (demand pressure: +2.58%) and a 2.45% reduction in PV generation (supply pressure: +2.55%). At the simulated thermal-loss coefficient (Uc = 20 W/m²K), the annual balance changes from a 3,266 kWh surplus in 2025 to a 778 kWh deficit in 2050 (DF = −0.99% ± 1.50%). Across Uc = 15–20 W/m²K, the mounting-dependent divergence ranges from −0.99% to −4.59%, while a propagated flush-mounted-plus-urban-heat-island case reaches −5.25%. Seasonal DF ranges from −29.60% in summer to +29.93% in winter, and grid-dependent operation increases from four to five months. These seasonal patterns are pronounced, although season-specific uncertainty was not propagated. The study demonstrates that annual balance alone can conceal substantial intra-annual grid dependence and supports incorporating climate-adjusted, seasonal performance indicators into NZEB design and certification. The DF is scenario-agnostic; CMIP6 SSP validation remains a priority for wider application and validation.