<ArticleTitle>Auditing Short-Term Load-Forecasting Claims on a Constructed Demand Dataset: Chronological Validation, Baseline Diagnostics, and Uncertainty Stress Tests</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage></FirstPage>
			<LastPage></LastPage>
			<ELocationID EIdType="pii">4001</ELocationID>
			
<ELocationID EIdType="doi">10.22044/rera.2026.17897.1552</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Majid</FirstName>
					<LastName>Baseer</LastName>
<Affiliation>Faculty of Engineering University of Palermo Italy</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>06</Month>
					<Day>25</Day>
				</PubDate>
			</History>
		<Abstract>Short-term load forecasting (STLF) studies can report strong accuracy when target construction, data provenance, units, and forecast-time information are not audited. This study presents a methodological audit using 189,888 quarter-hourly records labelled from January 2020 to May 2025. Although complete, the dataset’s provenance cannot be independently verified, and its target follows the near-exact construction: Load = 1500 + 100(Temperature − 28). Load values are therefore reported in source units rather than asserted physical kW.&lt;br /&gt;
&lt;br /&gt;
The diagnostic contribution demonstrates how target reconstruction, chronological splitting, forecast-information checks, interpretable baselines, and explicit claim boundaries alter the interpretation of an apparently high-performing STLF experiment. Ordinary Least Squares is exact because it recovers the construction rule. Random Forest and Gradient Boosting are retained as falsification benchmarks, not evidence of algorithmic competition. Near-zero correlations and feature importance for other variables confirm that the dataset does not represent realistic multivariate or autoregressive demand dynamics.&lt;br /&gt;
&lt;br /&gt;
Because realized temperature appears to be available at prediction time, the nominal metrics represent ex-post conditional fit rather than deployable ex-ante forecasting accuracy. Without fabricating observations, an analytical stress test propagates temperature-forecast error and independent load noise through the recovered equation. Temperature-error standard deviations of 0.5, 1.0, and 2.0 °C imply RMSE values of 50, 100, and 200 source units, respectively, before behavioral noise. The study provides a reproducible audit protocol and negative methodological result: accuracy, uncertainty, renewable-integration relevance, and operational value cannot be inferred from constructed targets without verified measured demand, issue-time weather forecasts, renewable generation, and system constraints.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">short-term load forecasting</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">constructed dataset</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">weather-forecast error</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">uncertainty stress test</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">model governance</Param>
			</Object>