Tide, Wave and Hydro Power
Amirhossein Farhoudi; Rouzbeh Shafaghat; Behrad Alizadeh Kharkeshi
Abstract
The performance of tidal turbines hinges on geometric characteristics and wave-current properties. This study investigates the performance of a three-bladed, 1:6 scale horizontal axis tidal turbine (HATT), with a particular focus on the underexplored influence of flow direction—a critical factor ...
Read More
The performance of tidal turbines hinges on geometric characteristics and wave-current properties. This study investigates the performance of a three-bladed, 1:6 scale horizontal axis tidal turbine (HATT), with a particular focus on the underexplored influence of flow direction—a critical factor for bi-directional tidal sites. The effects of various variables, including pitch angle, flow direction, electrical load, and wave-current interaction under different tip speed ratios, were systematically studied. Power and moment of force coefficients (Cp and Cm) alongside their TSRs were considered as the objective functions. The wave characteristics of the Khoran Strait were scaled using Froude methodology. The Cp and Cm at the optimal pitch angle range for downstream flow do not exceed a maximum increase of 6.5% compared to the no-wave modes. When the HATT operates at its optimum variables, the power coefficient increased by 35% compared to the lowest level. However, due to the generator's characteristics, the increase in power and moment of force follows a non-linear trend. The variations in Cp and Cm at different TSRs also form a parabolic pattern. A key novel contribution of this study is the comprehensive comparison of upstream versus downstream flow configurations, revealing that the turbine's power and moment of force coefficients in the upstream flow state increase by 36.1% and 18.1%, respectively, compared to the same pitch angles in the downstream flow state, due to the absence of the nacelle impeding the current. This finding provides crucial design guidance for bi-directional tidal turbine installations.
Solar Thermal Engineering
Mahdi Rezaei Rad; Rouzbeh Shafaghat; Amirhossein Aghajani Afghan; Behrad Alizadeh Kharkeshi
Abstract
This experimental study introduces a solar humidifier-dehumidifier desalination model as a type of open-air-open water (OAOW) system; also, a new condenser with thermoelectric modules is applied in the dehumidifier unit. The experimental tests were done by considering climate conditions in the north ...
Read More
This experimental study introduces a solar humidifier-dehumidifier desalination model as a type of open-air-open water (OAOW) system; also, a new condenser with thermoelectric modules is applied in the dehumidifier unit. The experimental tests were done by considering climate conditions in the north of Iran (Mazandaran province, Babol), and the effect of the inlet air's temperature and flow rate on the system's functional characteristics and condenser was investigated to improve the performance. Sensors measured the data related to the fluid temperature and humidity of the cycle at different points; other data was also gathered by psychrometric chart and EES software. The results section investigates water generation rate, GOR, coefficient of performance (COP), and condenser efficiency. The results showed that the highest water production is 420 g/hr, and the highest GOR is 0.19. Also, the water production rate and COP increase as the inlet air temperature rises. At temperatures lower than 75o Celsius, due to the air saturation, the maximum point of the water production and COP occurs at a flow rate of 0.022 kg/s. at high temperatures, increasing the flow rate raises water production, and on the other hand, the COP in the condenser is 0.8 at the highest point. According to the economic analysis done for the proposed model, the freshwater cost is 0.098-0.049 $/year for one liter.