Document Type : Original Article

Authors

1 Assistant Professor , School Of Architecture And Urban Design , Shahid Rajaee Teacher Training University , Tehran , iran.

2 M.A. Student In Architecture , Institute for Higher Education ACECR Khouzestan, Ahvaz

3 Instructor. In Architecture , Institute for Higher Education ACECR Khouzestan , Ahvaz , Iran.

4 M.A. Student In Architecture , Institute for Higher Education ACECR Khouzestan, Ahvaz , Iran

10.22044/rera.2026.17610.1524

Abstract

In hot and semi-humid climates, natural ventilation plays a crucial role in enhancing indoor environmental quality. Atriums are recognized as architectural elements that facilitate daylight penetration and airflow, yet they remain underutilized in such climatic conditions. Inefficient air circulation in upper floors and uneven airflow distribution in surrounding corridors highlight the need to reconsider ventilation design strategies. This study aims to improve natural ventilation performance in atrium-adjacent corridors by exploring architectural interventions that enhance airflow patterns and thermal comfort. Independent variables included the number and arrangement of spatial elements, while dependent variables comprised airflow velocity, movement patterns, and indoor temperature. Empirical data were collected from the Central Library of Khuzestan Province between October 25 and November 25. Geometric modeling was conducted in SpaceClaim, and computational fluid dynamics (CFD) simulations were performed using ANSYS Fluent R3 2019. Among eleven design scenarios, Model 11 featuring inlet windows in stair cores and outlet vents on the second-floor ceiling demonstrated superior performance. Airflow velocity increased to 1.907 m/s, indoor temperature decreased to 302.57 K, and airflow uniformity was significantly improved. Significant improvements were also observed in outlet flux and turbulence intensity, while thermal comfort indices (PMV, PPD) confirmed acceptable comfort range according to ASHRAE standards. These interventions are cost-effective, easy to install, and applicable to existing buildings.

Keywords

Main Subjects

[1] A. Shayanian, and F. Mozaffari Qhadikolaei, (2024) “The Performance of Atriums in Optimizing Energy Consumption in Commercial Complexes in Central Tehran”, Islamic Art Studies, 19(45), 394-407, doi: 10.22034/ias.2020.250686.1368
 
[2] M.CheshmehNoor, F.Mehdizadeh Saradj, S.A. YazdanFar, S. A. (2020) “The effect of atrium adjoining spaces’ position in terms of light distribution and heat gain. Case study: Administrative building of Niroo”, Research Institute. Journal of Sustainable Architecture and Urban Design, 7(2), 119-134.
doi:10.22061/jsaud.2020.4617.1363
 
[3] Y.Pan, Y. Li, Z. Huang, G. Wu, G, (2010) “Study on simulation methods of atrium building cooling load in hot and humid regions”, Energy and Buildings, 42(10), 1654-1660.
 
[4] M.H, Ahmad, M. Rasdi, M. (2000) “Design Principles of Atrium Buildings for the Tropics. Malaysia”, Penerbit UTM,
 
[5] E. Mousavi, A. Bhattacharya, (2022) “Event based approach for modeling indoor airflow patterns”, Journal of Building Engineering Volume 51, 1 July, 104244.
 
[6] A.A, Chowdhury, MG. Rasul, M.M.K.  Khan. (2022),” Thermal performance assessment of a retrofitted building using an integrated energy and computational fluid dynamics (IE - CFD) approach”, 7th International Conference on Advances on Clean Energy Research, ICACER 2022 April 20–22, Barcelona, Spain.
 
[7] J. Shaeri, M.J Mahdavinejad, R. Vakilinejad , H.  Bazazzadeh, M, A. Monfared. (2023)” Effects of sea-breeze natural ventilation on thermal comfort in low-rise buildings with diverse atrium roof shapes in BWh regions”, Case Studies in Thermal Engineering, Volume 41, January.
 
[8] F. Xu, C. Li, H. Tang. (2022)” Influence analysis of space configuration on cooling load of a large semi-closed atrium in hot and humid region”, Building and Environment, Volume 225, November.
 
[9] N. A , Mohd Fohimi, M. Hanif Asror, R. Rabilah ,M. Mahadzir Mohammud, M.Fauzi Ismail, Mohd,F. Nasir Ani, (2020) “CFD Simulation on Ventilation of an Indoor Atrium Space”, CFD Letters, 12, Issue 5, 52-59.
 
[10] R.Sokkar, H.Z Alibaba. (2020),” Thermal Comfort Improvement for Atrium Building with Double-Skin Skylight in the Mediterranean Climate”, Sustainability, 12.
 
[11] J.Oang, Z.Fan , M.Yang , J.Liu , R.Zhang , W.Wang , L.Sun , (2023) “Effects of complex spatial atrium geometric parameters on the energy performance of hotels in a cold climate zone in China”, Journal of Building Engineering, Volume 72, 1 August.
 
[12] C. Xu,Y. Wang, J. Hui, L. Wang, W. Yao, L. Sun, (2023) “Study on winter thermal environmental characteristics of the atrium space of teaching building in China's cold region, Journal of Building Engineering”, Volume 67, 15 May.
 
[13] P. Wu, J. Zhou,N. Li (2021) “Influences of atrium geometry on the lighting and thermal environments in summer: CFD simulation based on-site measurements for validation”,Building and Environment Volume 197, 15 June.
 
[14] W. Lan, H. Qiong, Z. Qi, X. Hong, R.K. K. Yuen, (2017) “Role of atrium geometry in building energy consumption: The case of a fully air-conditioned enclosed atrium in cold climates”, China, Energy and Buildings Volume 151, September, Pages 228-241.
 
[15] P. Pawar, D. Zhang, X. Wu, W. Lang, (2021) “Thermal performance of a non–segmented and segmented tall atrium in hot and humid clima “, Journal of Physics: Conference Series, Cisbat.
 
[16] D.P Albuquerque, N. Mateus, M. Avantaggiato , G. Carrilho Da graca. (2020),” Full-scale measurement and validated simulation of cooling load reduction due to nighttime natural ventilation of a large atrium, Energy and Buildings”, Volume 224, 1 October.
 
[17] A. Asthana, R. Sethuramlingam, P. Weston, M. Goel, and S. Kandasamy, (2019), “Prediction of Thermal Performance of Glass Roof Atriums using CFD Modelling “, The International Conference on Energy and Sustainable Futures (ICESF). Nottingham Trent University Pubilcations , September.
 
[18] D. Xu, Y. Li, T. Du, H.  Zhong, Y.Huang , L. Li, D. Xiangling, Duanmu, (2024) “Investigating the influence of outdoor temperature variations on fire-induced smoke behavior in an atrium-type underground metro station using hybrid ventilation systems” , Energy , Volume 287, 15 January.
 
[19] Z. Zhaoji,Y. Zhang, J. Mai, F. Wang, Y. Zhai, Z. Zhang, (2023)” Adaptation-based indoor environment control with night natural ventilation in autumn in an office building in a hot-humid area”, Building and Environment, Volume 243, 1 September.
 
[20] Z.Hedayat, B.Belmans, M.H Ayatollahi, I.Wouters , F. Descamps, (2015)” Performance Assessment of Ancient Wind Catchers: An Experimental and Analytical Study” Energy Procedia.
 
[21] M. Hazbei, Z. Adib, and F. Nasrollahi, (2014) “Natural ventilation effect on Shavadoons in Dezful by applying CFD modeling”, The Monthly Scientific Journal of Bagh-e Nazar, 11(30), 37-48.
 
[22] M. Oliaei, M Jahangiri, H. Mari Oriyad M. Rismanchiyan , A. Karimi, (2014) “Effective Factors on Indoor Air Quality in an Office Building in Tehran”, J Health Syst Res 2013; 8 (7) :1331-1340.
 
[23] A.Roasaei, and, O.Rahaei, (2020)” Improvement of Indoor Air Flow Quality under the Influence of Internal Partition Walls in Air-Conditioned Office Spaces Using CFD Method”, Armanshahr Architecture & Urban Development, 13(30), 69-81.
doi:10.22034/aaud.2020.101584.132.
 
[24] R. Al Waked, M. Nasif, N. Groenhout , L. Partridge (2021), “Natural ventilation of residential building Atrium under fire scenario”, Case Studies in Thermal Engineering, Volume 26, August.
 
[25] O.Rahaei, and H. R. Azemati, (2020) “Improving the Quality of Natural Ventilation in Classrooms of Mazandaran Province Based on the Position of the Openings Using CFD Method”, Journal of Iranian Architecture & Urbanism (JIAU), 11(1), 57-71,. doi: 10.30475/isau.2020.161257.1140.
 
[26] H.Ma , Y. Tu, X. Yang, Z. Yang, C.Liang, (2022) “Influence of tunnel ventilation on the indoor thermal environment of a poultry building in winter”, Building and Environment, Volume 223, September, 109448.
 
[27] S.khaksefidi, B.Vasigh, & M. Taban, (2020)” Proper design of the central courtyard in residential areas against Sadobist-roz-e winds in Zabol using CFD analysis”, Journal of Spatial Analysis Environmental Hazarts, 7(1), 197-212.
Sid.https://sid.ir/paper/407839.
 
[28] h. Montazeri, f. Montazeri, (2017) “CFD simulation of cross-ventilation in buildings using rooftop wind-catchers: Impact of outlet openings”, Renewable energy.
 
[29] S.a.k. Ijaz Fazil, K. Sivamoorthy, S. Ferozkhan, (2017) “Performance evaluation of air flow and thermal comfort in the room with wind - catcher using different CFD techniques under neutral Atmospheric Boundary Layer”, World engineers’ summit - applied Energy symposium & forum: low carbon cities & urban energy joint conference, july .
 
[30] D. Liu, G. Li, X. Wu, J. Wang, A. Hu, Q. Yan, X. Yang, H. Zhou, (2023)” Comparative analysis of heating characteristics of convective-radiant systems using various terminal air source heat pumps”, Energy and Buildings, Volume 301, 15 December.
 
[31] O.Rahaei, (2021)” Investigation of air flow pattern in the central courtyard in Qajar houses of Isfahan by CFD method,” Journal of Sustainable Architecture and Urban Design, 9(2), 46-25.
doi: 10.22061/jsaud.2021.6012.1597.
 
[32] Y. Wu, H. Sun, Z. Yang, M. Duan, B. Lin, H. Zhao, (2023) “Dynamic process simulation of indoor temperature distribution in radiant convective heating terminals”, Building and Environment, Volume 244, 1 October.
 
[33] M. Ansarimanesh, N. Nasrollahi, and M.J, Mahdavinejad, (2019)” Determination of the Optimal Orientation in the Cold Climate Administrative Buildings; Case Study: Kermanshah”, Armanshahr Architecture & Urban Development, 12(27), 1-9. doi: 10.22034/aaud.2019.92428.
 
[34] A. Ghaffari, M. Amidpour, A.R. Khodayari, & N. Mehrfarzam , (2018)” Design and Implementation of a Novel Algorithm for Optimal Building’s HVAC Systems Selection”, Journal of Mechanical Engineering (Isme) (Iranian Journal of Mechanical Engineering-English), 20(3), 59-79.
SID. https://sid.ir/paper/83554/en.
 
[35] J. Tavoosi , & M. Valizadeh, (2021)” Designing a new intelligent control system for ventilation of buildings to reduce energy dissipation”, Journal of Environmental Science And Technology, 23(6 (109) ), , 245-259. SID. https://sid.ir/paper/953816/en.
 
[36] A. Karimpour, D. Diba, & I. Etessam, (2019) “Economic Analysis and Assessing Energy Performance of Simulation-Powered Optimal Window Type and Window to Wall Ratio for Residntial Buildings in Tehran”, Hoviat Shahr, Vol 13, No. 39, Autumn.
 
[37] M.H. Shirazian, S.B Hosseini, & S. Norouzian Maleki, (2014)” A Comparative Study of Facade Samples in Residential Buildings of Tehran by Analytical Hierarchy Process (Ahp)”, Hoviateshahr, 8(18), 61-70. SID.https://sid.ir/paper/154645/en.
 
[38] F. Mahlab, and M. Shafiepoor, (2014)” The impact of optimizing energy consumption on indoor air quality Case Study: Educational Building,” Journal of Environmental Studies, 40(4), 1011-1021.
doi: 10.22059/jes.2014.53016.
 
[39] W. Liao, J. Peng, Y. Luo, Y. He, N. Li, A, Yongga ,(2022)” Comparative study on energy consumption and indoor thermal environment between convective air-conditioning terminals and radiant ceiling terminals”, Building and Environment Volume 209, 1 February.
 
[40] M.M. Moulaei, P. Pilechiha, & A. Shadanfar, (2019)” Optimization of Window Proportions with an Approach to Reducing Energy Consumption in Office Buildings”, Naqshejahan,9(2),117-123,
SID. https://sid.ir/paper/249054/en.
 
[41] A. Ebrahimpour, & Y. Karimi Vahid, (2011)” Optimal strategies for energy consumption reduction in a university building in Tabriz,” Modares Mechanical Engineering Journal, 12(4), 91–104.
 
[42] F. Hashemi, and S. Heydari, (2012)” Optimizing Energy Consumption in Residential Buildings in Cold Climates”, Soffeh, 22(1), 75-86.
 
[43] A. Mirza Mohammadi, (2017)” Energy conservation through adherence to green architecture principles”, Shebak Scientific Monthly, 3(9), Issue 28, December.
[44] M. Alwetaishi, M. Gadi, (2021) “New and innovative wind catcher designs to improve indoor air quality in buildings”, Energy and built environment.
 
[45] S. Jafarian, E. Sarkardehee, D. Monsefi Parapari, and M.R. Mojahedi, (2023)” Simulation and evaluation of the effect of membrane canopy on outdoor thermal comfort in Semnan city”,Journal of Iranian Architecture & Urbanism (JIAU), 14(1), 5-19.
doi: 10.30475/isau.2023.262631.1596.
 
[46] P. Baghaie, M.Ansari, M.R Bemanian, R.  Fayaz, (2015) “The Ramge of Thermal Comfort in Traditional Residential Outdoor in Yazd”, Hoviatshahr ,23(9),59-72.
 
[47] Hejazi Zadeh, Z., & Karbalaei Dareie, A. (2015). Thermal comfort in Iran. International Scientific Research Quarterly of the Iranian Geographical Society, 13(46), Autumn.
 
[48] A. Saeedi, & M. Toulabi Nejad, (2014)” Thermal comfort and climate-responsive architecture in Khorramabad County”, International Scientific Research Quarterly of the Iranian Geographical Society, NewSeries,12(40), Spring.
 
[49] Y. Zhao, K. Zhao, J. Lu, J. Ge, (2023)” Investigating the temperature distribution of non-enclosed atriums with air infiltration in winter”, Building and Environment, Volume 236, 15 May.
 
[50] Y.Dashtizadeh, & S.A.H. Garkani, (2018) “Assessment of thermal comfort range in an adobe house in Lasjerd village, Semnan Province”, Housing and Rural Environment Journal, (163), Autumn.
 
[51] Sh. Heydari, (2012)” Interaction of airflow, temperature, and comfort in urban open spaces: A case study of Iran’s hot and dry climate”, Fine Arts–Architecture and Urban Planning Journal, 17(2), Summer.
 
[52] Sh. Heydari, & Sh. Ghafari Jabbari, (2010) “Determining the thermal comfort time range for Tabriz city”, Modares Mechanical Engineering Journal, 10(4), 37–44, Winter.
 
[53] S. Almazmumi, J. S. Owen, C. Jimenez-Bescos and J. K. Calautit, (2025)” Numerical modeling and wind tunnel testing of a novel wall windcatcher natural ventilation system for multi-floor buildings”, Energy and Buildings, 349, 116427.
Doi: 10.1016/j.enbuild.2025.116427
 
[54] C. Wang, W. Wang, J. Qu, Q. Wang, X. Wang, and X. Liu, (2025)” Multi-Scale Validation of CFD Simulations for Pollutant Dispersion Around Buildings”, Processes, 13(12), 4076.
 
[55] S. Liu, W. Pan, Q. Cao, Z. Long, Y. Jiang and Q. Chen, (2019)” CFD simulations of natural cross ventilation through an apartment with modified hourly wind information from a meteorological station”, Energy and Buildings,195,16-25.
Doi: 10.1016/j.enbuild.2019.04.043.
 
[56] C. Ding, K. P. Lam and N. H. Wong, (2016)” Coupled Natural Ventilation Modeling for Contextual Parametric Design Decision Support”, Procedia Engineering, 169, 264-271.
Doi: 10.1016/j.proeng.2016.10.032.
 
[57] I. H. Hatif, K. Y. Wong, I. J. Al-Rikabi, H. Tan, H. Y. Kek, M. N. Hawas, M. Zhang, J. Zhang and T. Cai, (2026)” A multi-criteria CFD investigation of mixing, displacement, and stratum ventilation: Trade-offs between energy efficiency, thermal comfort, and airborne infection control”,Building and Environment, 289, 114042. Doi: 10.1016/j.buildenv.2025.114042.
 
[58] Y. Li, H. Huang, D. Duan, S. Shen, D. Zhou and S. Liu, (2024)” Non-Condensation Turbulence Models with Different Near-Wall Treatments and Solvers Comparative Research for Three-Dimensional Steam Ejectors”, Energies, 17(22), 5586.
Doi: 10.3390/en17225586.
 
[59] M. Hajdukiewicz, F. J. González Gallero, P. Mannion, M. G.L.C. Loomans and M. M. Keane, (2024)” A narrative review to credible computational fluid dynamics models of naturally ventilated built environments”, Renewable and Sustainable Energy Reviews, 198, 114404.
Doi: 10.1016/j.rser.2024.114404.
 
[60] X. Zhang, A.U. Weerasuriya and K.T. Tse, (2020)” CFD simulation of natural ventilation of a generic building in various incident wind directions: Comparison of turbulence modelling, evaluation methods, and ventilation mechanisms”, Energy and Buildings, 229, 110516.
 
[61] P. C. Liu, H. T. Lin and J. H. Chou, (2009)” Evaluation of buoyancy-driven ventilation in atrium buildings using computational fluid dynamics and reduced-scale air model”, Building and Environment, 44(9), 1970-1979.
Doi: 10.1016/j.buildenv.2009.01.013.
 
[62] G. Evola and V. Popov, (2006)” Computational analysis of wind driven natural ventilation in buildings”, Energy and Buildings, 38(5), 491-501. doi: 10.1016/j.enbuild.2005.08.008.
 
[63] Q. Chen, (1995)” Comparison of Different k-ε Models for Indoor Air Flow Computatuins. Numerical Heat Transfer, Part B: Fundamentals, 28(3), 353–369.
Doi: 10.1080/10407799508928838.
 
[64] Deputy for Planning and Human Capital Development, Ahvaz Municipality. (2023). Statistical Yearbook 2023. Available at:
https://planning.ahvaz.ir/Portals/3/FilesSubDomain/pdf/1403/amarnameh-1403.pdf

[65] Ahvaz Municipality. Official Website of Ahvaz Municipality. Available at: https://ahvaz.ir
[66] Khuzestan Meteorological Organization. Official Website of Khuzestan Meteorological Organization. Available at: https://khzmet.ir
 
 
[67] Office for Compilation of National Building Regulations, Ministry of Roads and Urban Development, Building and Housing Research Center. (2025). National Building Regulations, Part 19 – Energy Conservation (Fifth Edition).
 
[68] E. Sa’adati, & M. Zeynolabedini, (2015) “Principles of basic and advanced computational fluid dynamics simulation using Fluent and CFX, with tutorials on Gambit, TGrid, ICEM-CFD, and CFD-Post”, Pardad PetroDanesh Engineering Co., First Edition.
 
[69] O. Rahaei, and Z. Poorsayahi,” (2022)”. Improving the climate performance of solar chimneys for Ahvaz houses in south equator-facing rooms, Journal of Iranian Architecture & Urbanism (JIAU), 13(1), 245-257.
doi: 10.30475/isau.2022.221907.1365